AIRWAY DIFFICULTY DURING ANESTHESIA INDUCTION OF A NEWBORN WITH PIERRE ROBIN SYNDROME (SEQUENCE)

GMJ 2008;19(2):77-79
1. Gazi Üniversitesi Tıp Fakültesi Anesteziyoloji ve Reanimasyon A.D.
2. Gazi Üniversitesi Tıp Fakültesi Plastik, Rekonstrüktif ve Estetik Cerrahi A.D.
No information available.
No information available
PDF
Cite
Share
Request

ABSTRACT

10-day old infant with cleft palate was scheduled for suturing of the tongue to the lower lip under general anesthesia because of the difficulty in feeding and respiration prior to corrective surgery. In this case report, difficulty in providing and maintaining the airway was presented

Keywords:
Pierre Robin Syndrome, Newborn Airway, Intubation